MEAN-WELL MW PD-40A 40W 5V 12V Dual Output Switching Power Supply 110V 220V AC to DC 5V 12V 5A 2.5A PCB Type Open Frame SMPS Adapters


Tk 552
Tk 650
Tk 650
15% OFF
  • Open Frame type
  • PD-40 series, 40W max power out
  • AC90~264V 47/63Hz in Full range
  • DC out max : V1=5V 5A, V2=12V 2.5A
  • Ripple noise : 5V: 50mV, 12V: 150mV
  • Voltage adj. range : 4.75~5.5 for V1 (5V)
  • Line regulation : 5V: +/-0.5%, 12V: +/-2%
  • Load regulation : 5V: +/-1%, 12V: +/-4%
  • Efficiency : 71%
  • Protection type : Hiccup mode, recovers automatically after fault condition is removed.
  • Protection : Short circuit / Overload / Over voltage
  • 100% full load burn-in test
  • UL TUV CB CE safety, RoHS
  • Outside dimension : 107*61*28mm (L*W*H)



Description: 40W 5V 12V Dual Output Switching Power Supply 110V 220V AC to DC 5V 12V 5A 2.5A

MEAN-WELL MW PD-40A 40W 5V 12V Dual Output Switching Power Supply 110V 220V AC to DC 5V 12V 5A 2.5A PCB Type Open Frame SMPS Adapters

Specifications:

  • Open Frame type
  • PD-40 series, 40W max power out
  • AC90~264V 47/63Hz in Full range
  • DC out max : V1=5V 5A, V2=12V 2.5A
  • Ripple noise : 5V: 50mV, 12V: 150mV
  • Voltage adj. range : 4.75~5.5 for V1 (5V)
  • Line regulation : 5V: +/-0.5%, 12V: +/-2%
  • Load regulation : 5V: +/-1%, 12V: +/-4%
  • Efficiency : 71%
  • Protection type : Hiccup mode, recovers automatically after fault condition is removed.
  • Protection : Short circuit / Overload / Over voltage
  • 100% full load burn-in test
  • UL TUV CB CE safety, RoHS
  • Outside dimension : 107*61*28mm (L*W*H)

Features

  • Universal AC input / Full range
  • Low leakage current<0.5mA
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • 100% full load burn-in test
  • Fixed switching frequency at 100KHz
  • Low cost
  • High reliability






  • Open Frame type
  • PD-40 series, 40W max power out
  • AC90~264V 47/63Hz in Full range
  • DC out max : V1=5V 5A, V2=12V 2.5A
  • Ripple noise : 5V: 50mV, 12V: 150mV
  • Voltage adj. range : 4.75~5.5 for V1 (5V)
  • Line regulation : 5V: +/-0.5%, 12V: +/-2%
  • Load regulation : 5V: +/-1%, 12V: +/-4%
  • Efficiency : 71%
  • Protection type : Hiccup mode, recovers automatically after fault condition is removed.
  • Protection : Short circuit / Overload / Over voltage
  • 100% full load burn-in test
  • UL TUV CB CE safety, RoHS
  • Outside dimension : 107*61*28mm (L*W*H)
Customer Questions and answers :

Login to ask a question