Voltmeter & Ammeter Blue & Red LED Amp Dual Digital Volt Meter Voltage Current Meter Mini Digital Voltmeter Ammeter Tester 0.56 inch LED Display Electrical Circuitry and Parts Volt meter and Ammeters


Tk 225
Tk 500
Tk 500
55% OFF


Description: DSN-VC288 DC 100V 10A Voltmeter & Ammeter Blue & Red LED Amp Dual Digital Volt Meter Voltage Current Meter

DSN-VC288 VC288 DC 100V 10A Voltmeter & Ammeter Blue & Red LED Amp Dual Digital Volt Meter Voltage Current Meter Mini Digital Voltmeter Ammeter Tester 0.56" LED Display

Specifications:

  • Voltage measurement range:0.0V-100V
  • Current test range:0-999mA, 0-10A, 0-50A, 0-100A
  • Power supply range:DC4-30.0V
  • Voltage error:±0.1%
  • Current error:±1%
  • External shunt specifications:75 milliohms
  • Working current< 20mA
  • Refresh rate: About 300mS once
  • Display method: Double three 0.28" LED digital tube
  • Display Color: Red + Blue
  • Lead length:15cm
  • Dimensions:48 x 29 x 22 mm
  • Mounting holes:46 x 27 mm
  • Operating temperature:-10°C~65°C

Features:

  • Working voltage of Meter itself:DC 4 - 30V
  • Working current of Meter itself:≤20mA
  • Voltage Measuring range: DC 0 - 100V
  • Current Measuring range: DC 0 - 9.99A
  • Voltage resolution (V): 0.1V
  • Current resolution (A): 0.01A
  • Measure accuracy: 1% (± 1 digit)
  • Display: 0.28" digital tube, Two color blue and red
  • Refresh rate: about 300mS / times
  • Dimensions:48mm*29mm*26mm
  • Operation Temp: -10℃-+65℃

Wire Connection:

  • Thin Red line (VCC): Power Supply + (DC 3.5-30V +)
  • (if the measure voltage between DC 3.5-30V, then the Thin Yellow line and Thin Red line can connect together)
  • Thin Black line (GND): Power Supply - (DC 3.5-30V -), Measure Voltage - (DC 0-100V -)
  • Thin Yellow line (VIN): Measure Voltage + (DC 0-100V +)
  • Thick Red line (I+): Current Input +
  • Thick Black line (I-): Current Input -
  • More detail please check the description picture.

Error Phenomena:

  • Due to the aging of the device and change of ambient temperature1. The error becomes larger when measuring small current.Solution: When there is no load, short-circuit 2 pads of KEY and then power on, the module will automatically do zero calibration, after that shut off the module and cut the short circuit point.
  • 2. The error becomes larger in whole measurement rangeSolution: When connecting load(half of the range is best), keep adjusting R7 until it displays the same value with the more advanced calibration source.





Customer Questions and answers :

Login to ask a question